(1) The crusher can only be fed into production after it is in normal operation.
(2) The material to be crushed should be evenly fed into the crusher cavity, and side feeding or full feeding should be avoided to avoid unilateral overload or overload.
(3) During normal operation, the temperature rise of the bearing should not exceed 30°C, and the maximum temperature should not exceed 70°C. When the above temperature is exceeded, stop the vehicle immediately, find out the cause and eliminate it.
(4) Before stopping the machine, the feeding should be stopped first, and the power can only be turned off after the materials in the crushing chamber are completely discharged.
(5) When crushing, if the machine stops due to the blockage of materials in the crushing chamber, the power should be turned off immediately to stop the operation, and the materials in the crushing chamber should be cleaned before starting again.
(6) After one end of the jaw plate is worn, it can be turned around for use.
(7) After the crusher has been used for a period of time, the adapter bushing should be loosened to damage the machine.